Automatic Extinguisher Control Panel Extinguisher System
HomeHome > Products > Automatic Control System > Automatic Extinguisher Control Panel Extinguisher System
Automatic Extinguisher Control Panel Extinguisher System

Automatic Extinguisher Control Panel Extinguisher System

AUTOMATIC EXTINGUISHER CONTROL PANEL Conventional Fire Fighting Panel Introduction The automatic extinguisher control pa
Basic Info.
Model NO. CM1004
Receive Frequency 485
Wiring Mode Sub-Line System
Number of Zones 4
Power Supply Rating 3 [email protected]
Primary AC 90-270VDC
Color Red/Gray
Weight 5kg
Transport Package Carton
Specification 37*440*100mm
Trademark panel
Origin China
HS Code 8531100000
Production Capacity 500000/Month
Product Description

Automatic Extinguisher Control Panel Extinguisher System



AUTOMATIC EXTINGUISHER CONTROL PANEL Conventional Fire Fighting Panel
Introduction
The automatic extinguisher control panel is designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguish ing system and has three detection zones, any or all of which are capable of contributing to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.
In addition to the requirements of EN54-2 the control panel has the following facilities:
Test condition to allow the automatic resetting of zones in alarm for testing purposes. EN54-2 Section 10 option with requirements
Delay of the actioning of fire alarm devices (sounders) so that an alarm may be verified before a premises is evacuated. EN54-2 Section 7.11 option with requirements.
Fire alarm devices to enable an audible warning to be sounded throughout premises upon the detection of a fire condition or the operation of a manual call point. EN54-2 Section 7.8 option with requirements
In addition to the requirements of EN54-2, all control panels have voltage free relay contacts for fire and local fire which operate upon a fire condition. These are to be used for local control and signaling.
In addition to the requirements of EN12094-1 the control panel has the following facilities:
Delay of extinguishing signal of up to 60 seconds. EN12094-1 Section 4.17 option with requirements.
Signal representing the flow of extinguishing agent to indicate the released condition. EN12094-1 Section 4.18 option with requirements.
Monitoring of the status of components by way of a low pressure switch input. EN12094-1 Section 4.19 option with requirements.
Emergency hold device to enable the extinguishant delay time to be extended. EN12094-1 Section 4.20 option with requirements.
Control of flooding time to deactivate the releasing output after a set period of time. EN12094-1 Section 4.21 option with requirements.
Manual only mode to disable the release of extinguishant via automatic detection devices. EN12094-1 Section 4.23 option with requirements.
Triggering of equipment outside the system by way of first and second stage contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirements
Activation of alarm devices with different signals to indicate pre-discharge and released warnings using different sounds. EN12094-1 Section 4.30 option with requirements.